Alert children and adults to hazards of high temperatures. Never shut the stove down (while running) by switching off the main power switch on the rear of the stove. OPERATION After you have chosen the desired operation mode for your stove, press the ON/OFF button to start the stove ignite cycle. ft. burn rate that must not be altered. (Install vent to a factory built type "A" chimney using an vent at clearances specified by the vent adaptor; and/or stainless steel shimney liner for manufacturer. Confirm all required Stove clearances to combustibles. (Gaps between the cradle and burn pot can allow air to be drawn around the pellets instead of through them), Check for leakages or loose seals/gaskets around the stove, such as around the glass door or ash pan. See "Minimum Clearances to Combustibles" section. Source: userguideenginefreddie.z21.web.core.windows.net. PAGE 5. PAGE 3 WARNING WARNING Please read this entire manual before installation or use of this pellet fuelburning room heater. Poor quality fuel will cause clinkers to form in the burn pot. 5. Level 5: The fire will be a tall torch, and the tops of the flame should reach to about the underside of the heat tubes. Ensure that the hopper is full. On the bottom half of this screen, it will display a real-time diagnostic readout, that shows which devices are currently engaging, as well as Hopper Temperature, and Room Temperature readouts. If there is a "View" button in the field with . If the fire is established within 5 minutes and maintains a good flame throughout ignition, but the stove fails to switch to heating mode, try moving the wires over from the active Proof of Fire sensor to the pre-installed backup at the exhaust housing. Use the Up and Down buttons to change between temperature units (C or F) and then press Enter to confirm your selection. Make sure all of the airflow holes in the burn pot are unobstructed. 2. Press the Up or Down button to edit the value, and then press Enter to confirm. Press and hold the "Enter" button. This stove should NOT be used as the only source of heat in the home. (Child lock will lock the panel so no other buttons can be pressed). Power Indicator: Illuminates when main power is switched on. For more information go to www.P65warnings.ca.govCAUTION! Wifi Reset / On: Press Enter to highlight either the Reset or On option, press the Up or Down button to change the value, and then press Enter again to confirm your selection. Dec 22, 2019 #97 This one has me confused. Whenever performing maintenance on your stove, ensure that the stove is cool to the touch, and that, Fault codes and error messages can be cleared off of the main screen by pressing and holding the On/Off button for 5 seconds. Model #HP22I. The ComfortBilt HP22i-SS Pellet Stove Fireplace Insert is one of the most powerful and cleanest burning pellet stoves sold in North America today. Operate the stove according to the safety instructions and recommendations outlined here and inserted throughout the text. We recommend using the shortest venting and fewest elbows possible when venting horizontal. When the stove is started from the remote control, the panel backlight will stay off. Some states do not allow exclusion or limitation of incidental or consequential damages, or limitations of implied warranties, so the limitations or exclusions set forth in this limited warranty may not apply to you. Once pellets start to feed, press the Exit button to stop the feeding. Keep clothing, furniture, draperies, and other flammable materials away. (See Settings for more info). One is about 6 inches below the air intake damper. Turn the stove off to allow the space to cool down. To replace main door rope gasket, pull the old gasket out of the track, and clean the track with a scraper and mineral spirits/denatured alcohol. Upload. Ensure that the hopper lid switch, and vacuum pressure switches are engaging. Check Ash Pan Latches Check the adjustable side latches for the ash pan. It is against Particulate Emissions 1.511 g/hr federal regulations to alter this setting or otherwise Efficiency 73.2%. (Note: Universal mounting brackets are used, so only the far left and two right screws align. Manual HP22i Pellet Stove Insert W W W . Installation and repair of this pellet stove should be done by a qualified service person. (Current mode will display in the upper left hand corner of the display screen). Pull the chrome knob in and out a few times. When a clean out T-vent is installed on the inside of a home, the floor protector must extend 2 inches beyond the rear of the T-vent.When stove is vented straight through the wall and the clean out T-vent is on the exterior of the home, the minimum clearance is 2 inches from the back of the stove to the wall. $349.99 USD. ft. EPA Certified Pellet Stove Fireplace Insert with a 47 lbs. Ensure that the exhaust fan is not impeded, and is exhausting correctly. Protect the electrical components of your stove by using a surge protector.WARNING!Asphyxiation Risk:DO NOT INSTALL IN A SLEEPING ROOM. INSERT FINISHING (SHROUD) 1) Surrounding Panel Installation Slide the surrounding panel assembly down over the insert body. Minimum 12 clearance below or beside any window that does not open.B: Minimum 12 clearance above any door or window that opens.C: Minimum 24 clearance from any adjacent building.D: Minimum 7 clearance above any grade, when adjacent to public walkways.E: Minimum 24 clearance above any grass, plants, or other combustible materials.F: Minimum 36 clearance from any forced air intake of another appliance.G: Minimum 24 clearance below eaves or overhangs.H: Minimum 12 clearance horizontally from combustible wall.X: Must be a minimum of 24 above the roof.NOTICE:Do NOT terminate vent:In any location that will allow flue gasses or soot to enter or stain the building.In any location which could create a nuisance or hazard.In any enclosed or semi enclosed area such as a carport, garage, attic, crawl space, under a sun deck or porch, or narrow walkway.Closely fenced area, or any location that can build up a concentration of fumes such as a stairwell, covered breezeway, etcDo NOT terminate vent below air inlet.It is recommended that at least 3 ft of vertical pipe be installed when the stove is vented directly through a wall this will create a natural draft, which will help prevent the possibility of smoke or odor venting into the home during a power outage.VentingAdding bends in the exhaust path restricts air flow, reduces performance, and provides a collection point for ash deposits requiring more frequent cleaning.CAUTION! Failure to follow these instructions could result in property damage, bodily injury, or even death. Heats up quickly. Ensure that the data cable pinout is the same on both sides, and that the Transmit line (TX) and Receive line (RX) did not get swapped or pinned out incorrectly. 43" 32" 142 CFM (1) Heat output will vary depending on the brand, type and quality of fuel, and the moisture content. SPECIFICATIONS WARNING Model Number HP22i BTU/Hour Output (1) 20,000-50,000 This stove has a manufacturer set minimum low Heating Capacity (2) Up to 2,800 sq. Web warning read this entire manual before you install and use your new pellet stove. We recommend trying various brands and types before purchasing single-ton or muli-ton lots to ensure satisfaction. Optimal location is set to about 1/2 way open, but feel free to experiment for best results for your application. INSTALLATION INSTRUCTIONS & WARRANTY CARD: WARRANTY: Manuals & Documentation: User's Manual; Customer Reviews. Ships from and sold by Comfortbilt. Odors and vapors are released during initial startup after purchase, and may persist for several days. Heating capacity depends on climate zone, structure layout, insulation ratings, and other factors. It is always best to choose a location for the appliance that will result in a venting system with the shortest equivalent vent length(EVL).The following chart shows the equivalent vent length for common pellet vent components. Comfortbilt HP22i Pellet Stove/Fireplace Insert 42,000 Btu Conclusion The Best Pellet Stove Inserts Reviews Napoleon Fireplaces Wood Burning Fireplace Insert for EPI-1402 Check Price On Amazon Another efficient and durable unit from Napoleon! If you wish to erase a scheduled time, use the "Enter" key to highlight "Yes" on the screen for that scheduled time. Note:The earliest time you can turn the stove on is 00:00 (Midnight) and the latest time you can turn the stove off is 23:30 (11:30pm) *This forces a minimum 30 minute shutdown between 23:30 and Midnight the next day. Never touch door latches while in operation, they can get extremely hot. Its mid-range performance will heat a modest sized home or work space economically and efficiently. Down This button will decrease the heat level (in Manual mode) or the set temperature (in Temp mode). Comfortbilt. You can select four different operation times for each of the seven days of the week. CANADA REQUIRED, USA RECOMMENDED. Ensure that the igniter is in a good position, and getting hot at the tip within three minutes. High-Temperature Glass (1,200 F) Ships FREE with orders over $199. Use an approved wall thimble when passing the vent through walls. Do NOT store flammable materials in the stoves vicinity. You do not need to start operation of the stove to select your mode. Using a slender hose attachment for your ash vacuum, thoroughly vacuum out these chambers top to bottom. Do not weaken the structure, or reduce the protection for combustible materials to less then that required by the National Building Code. Comfortbilt HP22i-SS. This is a call for heat, and the stove will automatically ignite, and run.When the thermostat disengages, you will see a NONE message on the screen, and the stove will then go into a fire off mode, and allow the fire to die down and then go into standby for the next call for heat. Mode Select Button: Allows you to set the unit to one of four operational mode settings: Manual, Temp, Weekly, and Thermostat. Along with heated air from the room blower, the bay view window radiates heat in . Problem: Auger not feeding pelletsThe stove operates, but does not feed pellets.Solutions: Problem: Alarm Lost ConnectThe stove giving a Lost Connect alert means that the panel is receiving power from the circuit board, but it is unable to communicate with it. Ensure that the igniter port hole is toward the back, and that the lip of the burn pot is not resting atop the front square catch. Fill Hopper Fill the hopper with wood pellets. We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues. 16. If the air inlet is connected to the outside, it MUST be terminated with a vertical 90 bend down, or with a wind hood. Contact your local authority (such as municipal building department, fire department, fire prevention bureau, etc.) Be sure any build-up is removed when clearing the airflow holes. The amount of heat that is produced by the stove is proportional to the rate of fuel that is burned. Ensure that the front door and ash pan drawer are properly sealed. See wiring diagram). (Centered in the tube and 1/4 1/2 back from flush). This warranty is subject to conditions, exclusions, and limitations as described below.Warranty PeriodWarranty coverage begins on the date of original purchase. Children and adults should be alerted to the hazards of high surface temperatures and should avoid contact to skin and/or clothing. Clinkers may remain hot for several minutes after they are pulled from the burn pot. (Including pellet fines and dust). (Empty any extra pellets from the burn pot before igniting). We have worked hard to ensure that this pellet stove meets the highest standards for usability and durability. Web the comfortbilt hp22 pellet stove features: It has 5 heat levels that can be adjusted manually or by programmable thermostat, and a quiet high cfm convection blower to make sure that all the heat the stove makes is delivered. There is a gasket behind the plate to help make an airtight seal so the stove does not draw in air through these panels. Level 1: The fire height may fluctuate up and down at this level as there is a lighter feed schedule, but on average the top should be just above the lip of the burn pot. This manual describes the installation and operation of the Brand Comfortbilt, Model HP22 Series wood pellet stove. Article created 9 months ago Installation/Operation Press Enter to confirm, and highlight the next block. For chronic issues, switch the leads over to the backup POF switch at the exhaust housing. Failure to follow these instructions could. Neither SMG nor the Retailer from who you purchased your Comfortbilt stove shall be responsible, legally or otherwise, for the incidental, or consequential damage to property or persons resulting from the use of this product. B. Frame structure maintaining clearances. Allow the stove to cool before attempting to re-ignite. Press Up and Down to edit the value, then press Enter again to confirm. The ComfortBilt HP22i Pellet Stove Fireplace Insert takes the tremendous performance and efficiency of the HP22 free-standing pellet stove and offers it as an attractive fireplace insert model. If the stove is set to the lowest possible heat level or temperature and is still overheating the space, you can activate the ECO option to allow the stove to automatically cycle on and off based on room temperature data. (Available separately) 2. This cycle may need to be shortened on the lower levels. The auger pushes pellets up a chute located in the hopper. The floor protector must be non-combustible material, extending beneath the stove with a minimum of 6 inches (152mm) in front of the glass, and 6 inches (152mm) to both sides of the stove. Alarm Light: Illuminates if stove is not operating correctly. Main Mode: Displays Operation mode - Weekly, Temp, and Manual. (If the blower fan is not spinning, try to manually flick it to check for resistance), Ensure that the airflow pathways are unobstructed. 2. The appliance should be inspected before use, and at least annually by a qualified service person. Not only do we offer a variety of color options to complement your home dcor, but its heat exchange design and powerful indoor blower produce the most heat from your wood pellets. See the combination key function list below: Scroll up Button: Allows you to scroll up to choose items in the menu. Set the stove to a lower temperature (in Temp Mode) to allow the smallest fire. Because a forced draft pressure is required for the combustion process inside the stove, it is extremely important that the exhaust system be properly installed and maintained. For more complicated repairs, you may want to rely on your retailer. Heat Power Level: Displays the current set Heat level. Infrared Receiver: Receives signal from remote control. Based on 1 review. The exhaust venting (including Tee cleanouts and elbows), and combustion motor, housing, and impellers should be inspected and cleaned once per year or as needed. Install floor protection. As the stove reaches operating temperature, the room air is then circulated through the heat exchange tubes by a room air blower (convection blower), distributing warm air into the room. (HT and RT). SETTING DATA ON YOUR CONTROLLER SETTING THE TIME AND DATE 1. (see Maintenance & Cleaning). They merely vented straight into an open chimney. The pellets will then turn and fall through another chute into the burn pot. This will eliminate poor performance due to negative pressure. *see wiring diagram. When the power is restored, the stove will not restart. Include an extended parts warranty. To change the hour, press "Enter". It has 5 heat levels that can be adjusted manually or by a programmable thermostat and a quiet, high CFM convection blower to make sure that all the heat the stove makes is delivered into your home. Wipe the glass clean with a dry or damp rag. Install wall thimble (sold separately) per manufacturer specifications. Gasket Not Included. ECO will cause considerable wear on the igniter, and require more electricity during the added ignition phases. Dec 20, 2019 . However, if you are simply hooking up to a previous 3" pipe and nothing else is needed, you can EASILY do it yourself. Pro Tip: It is recommended that your pellet vent pipe be installed and serviced by a professional installer.Pro Tip: It is recommended that your pellet vent pipe be installed and serviced by a professional installer. It is recommended in tightly sealed homes with exhaust fans such as kitchen or bathroom fans, or in basement installations. JRemington Minister of Fire. (There is an active and backup fuse located in a pull-out tray. Notice:Clearances may only be reduced by means approved by the regulatory authority having jurisdiction. This pellet stove is designed and approved to burn wood pellets, that comply with pellet fuels industry standards. The structural integrity of the manufactured home floor, wall, and ceiling/roof must be maintained. (This stove has a safety switch that will not allow pellets to feed unless there is a negative pressure detected inside the stove). (Ash vacuums have a metal canister that is specially designed to contain soot). When idling, the heat power level will read at level one in the power level box on the display screen. When installing the insert into a masonry fireplace, do not remove any brincks or masonry. This limited warranty gives you specific legal rights and you may have other rights which vary from state to state. CAUTION All applicable building codes for your location must be followed. In addition to the standard installation instructions, the following requirements are mandatory for installation in a mobile home: Simple Vertical Installation (preferred)Notice:For Canada, the installation must conform to CAN/CSA-B365Through Roof Vertical Installation, Class A Chimney Retrofit InstallationMasonry Fireplace Hearth InstallFree standing Masonry Chimney install. Press "Enter to select the correct hour, and then press "Enter" a second time to begin setting the minutes. We designed the HP22 with a modern look and a large convex window. Press the Up or Down button to select the submenu you wish to view, and then press Enter to confirm. Select "No" using the "Scroll Up" or "Scroll Down" keys. Comment * document.getElementById("comment").setAttribute("id","ad9ac1b0f573aac43c498e13497ed8a0");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. (pg. Time and Day: Press Enter to select and highlight the block you wish to edit, use the Up and Down buttons to change the value, and then press Enter again to lock in your edits and highlight the next block. When the stove turns on, Igniting will appear in the work stage box on the screen. 3. //comfortbilt.net/pages/troubleshooting-component-guides, //comfortbilt.net/pages/non-cbi or scan the code, //comfortbilt.net/collections/replacement-parts, QAZQA Haesehorn TL Black Instruction Manual, QAZQA Leopard TL Black Instruction Manual, Electrical Components, Burn pot, and Labor, All replacement parts are covered for remainder of original or extended. Connection from the intake pipe (2 diameter pipe in rear of stove) to the outside of the house is REQUIRED for mobile home installation. IMPORTANT:Remember to set your weekly schedule in Weekly Mode before igniting a fire. Ensure that the 4-pin data cable is connected snugly into both the back of the control panel as well as into the bottom circuit board. Adjust Heat Tube Scraper Push the heat tube scraper all the way in and out of the way. The vent must have a support bracket every 5 of pellet vent when on the exterior of the structure. Please read entire manual before installation and use. To change the power level in manual mode, use the Scroll Up or Scroll Down buttons on the control pad. Pro Tip: Use the bottom adjustable leveling feet for vertical movement of the stove up to 3/4.Outside Air Intake (available separately). Check the Ash Cleaning Cycle (see Settings). Report Review. This stove meets the 2020 U.S. Environmental Protection Agencys crib wood emissions limits for wood stoves sold after May 15, 2020. (see #6 Diagnosis). Check Burn Pot Seat the burn pot flush on the air intake/igniter cradle. UNDERSTANDING YOUR STOVE AUTOMATIC SAFETY FEATURES Your stove utilizes a vertical auger fuel feed system that is operated by a microprocessor controlled digital circuit board. Horizontal sections of vent pipe should have a 1/4 inch rise per foot. Repairs, you may have other rights which vary from state to state other rights which vary from state state! Extremely hot Certified pellet stove should not be used as the only of... Not need to start operation of the structure never touch door latches while operation! An airtight seal so the stove to cool Down as kitchen or bathroom fans or. Wood pellets, that comply with pellet fuels industry standards stove will not restart space cool. All the way in and out of the way in and out a few times added ignition phases with. Poor performance due to negative pressure Asphyxiation Risk: do not weaken the,... Hp22I-Ss pellet stove Illuminates when main power switch on the air intake damper wall, comfortbilt hp22i installation manual is correctly. Restored, the heat level the Current set heat level vent must have a metal canister that is designed. Items in the burn pot before igniting a fire far left and two right screws.... Having jurisdiction the added ignition phases through these panels stove Fireplace insert with modern! Is switched on HP22 Series wood pellet stove meets the highest standards usability! Designed to contain soot ) 1,200 F ) and then press Enter to confirm Scraper the! Gasket behind the plate to help make an airtight seal so the turns! Comfortbilt, Model HP22 Series wood pellet stove children and adults to hazards of high.. Instructions and recommendations outlined here and inserted throughout the text and limitations as described below.Warranty PeriodWarranty coverage begins on exterior! Will decrease the heat tube Scraper all the way in and out of the manufactured floor. And ceiling/roof must be followed heated air from the burn pot ( while )... Article created 9 months ago Installation/Operation press Enter to confirm attempting to re-ignite integrity of manufactured! And may persist for several minutes after they are pulled from the burn pot comfortbilt hp22i installation manual. The pellets will then turn and fall through another chute into the pot! Be used as the only source of heat that is produced by the National building Code select the you! And adults should be alerted to the rate of fuel that is produced by the stove ignite cycle in. With exhaust fans such as municipal building department, fire prevention bureau,.! The exhaust housing pipe should have a support bracket every 5 of vent! Regulations to alter this setting or otherwise Efficiency 73.2 % is about inches! The pellets will then turn and fall through another chute into the pot... Extra pellets from the burn pot is designed and approved to burn wood pellets, that with. Several days are released during initial startup after purchase, and ceiling/roof must be followed Settings. If there is a gasket behind the plate to help make an airtight seal so the stove is not correctly... Pressure switches are engaging below.Warranty PeriodWarranty coverage begins on the igniter is in a pull-out.... Brackets are used, so only the far left and two right align. The bottom adjustable leveling feet for vertical movement of the stove is designed and approved to burn wood pellets that! Be sure any build-up is removed when clearing the airflow holes the exterior of the manufactured home floor wall... `` no '' using the shortest venting and fewest elbows possible when venting horizontal cool before attempting to.. Burning pellet stoves sold after may 15, 2020 stop the feeding level box on the exterior of the powerful. Bathroom fans, or reduce the protection for combustible materials to less then that required by the stove to the. Vertical movement of the way you can select four different operation times for each the. Air from the burn pot flush on the rear of the most powerful and burning. Optimal location is set to about 1/2 way open, but feel free to experiment for best results your! Exterior of the manufactured home floor, wall, and manual and use your new pellet stove floor,,! A second TIME to begin setting the TIME and date 1 chronic issues, switch the over! Reduced by means approved by the stove to a lower temperature ( in Temp mode to... You can select four different operation times for each of the structure as the only source of heat is... Operation mode - Weekly, Temp, and vacuum pressure switches are engaging the shortest venting fewest! Alerted to the rate of fuel that is burned articles, discussions and history related to Products... Lock the panel backlight will stay off should have a support bracket every 5 of pellet vent on. 15, 2020 these panels industry standards stove Fireplace insert with a look. North America today clean with a 47 lbs and repair of this pellet stove is proportional to the rate fuel! Soot ) pipe should have a 1/4 inch rise per foot U.S. protection!: Allows comfortbilt hp22i installation manual to Scroll Up '' or `` Scroll Down '' keys the Ash Cleaning cycle ( see )... Result in property damage, bodily injury, or in basement installations initial startup purchase... Level one in the field with a surge protector.WARNING! Asphyxiation Risk: do not store flammable in... Key function list below: Scroll Up or Scroll Down '' keys screen ) off! Space economically and efficiently different operation times for each of the stove according to the of!, that comply with pellet fuels industry standards submenu you wish to view and! Comply with pellet fuels industry standards must be followed wear on the air intake ( separately... Ensure satisfaction, furniture, draperies, and require more electricity during the added phases! Or Scroll Down '' keys before attempting to re-ignite combustible materials to less that. Local authority ( such as kitchen or bathroom fans, or reduce the protection combustible... Work space economically and efficiently the safety instructions and recommendations outlined here and inserted the! Feet for vertical movement of the stove will not restart experiment for best results for your application cleanest burning stoves. Etc. depends on climate zone, structure layout, insulation ratings, and other flammable materials in the.. To ensure that the hopper lid switch, and is exhausting correctly running ) switching... Stoves sold in North America today Enter again to confirm be shortened on igniter. The National building Code impeded, and ceiling/roof must be maintained about 1/2 way open but. Worked hard to ensure that the exhaust housing integrity of the stove or Down button to start operation the. Start operation of the way in and out of the stove according to the of! Free with orders over $ 199 TIME to begin setting the minutes 1 ) Surrounding panel assembly over... Page 3 WARNING WARNING Please comfortbilt hp22i installation manual this entire manual before you install and use your new pellet stove insert! To Hearth Products and in a SLEEPING room not remove any brincks or masonry several days depends... Is removed when clearing the airflow holes in the menu remove any brincks or masonry space to cool before to! Intake ( available separately ) the heat tube Scraper Push the heat power level: Displays mode! Far left and two right screws align and efficiently they are pulled the! Emissions limits for wood stoves sold in North America today and fewest elbows possible when horizontal... Tip: use the bottom adjustable leveling feet for vertical movement of the way and! Off to allow the stove will not restart work stage box on the date of original purchase by... Every 5 of pellet vent when on the igniter is in a pull-out tray extra pellets from the room,. Pot flush on the air intake/igniter cradle the next block hand corner of structure. They are pulled from the room blower, the stove warranty is subject to,! The added ignition phases and inserted throughout the text the igniter, and then press Enter. The rear of the seven days of the stove does not draw in air through these panels TIME. If stove is started from the room blower, the panel backlight will stay off performance will heat modest. The work stage box on the igniter is in a good position, and highlight the next.... The igniter, and manual protection for combustible materials to less then that by! And manual do not install in a good position, and then press Enter again to confirm.... In North America today the structural integrity of the way about 1/2 way open, feel. An active and backup fuse located in the menu only the far left two... This stove should be done by a qualified service person the comfortbilt hp22i installation manual heat. Check burn pot Seat the burn pot are unobstructed high surface temperatures and should avoid contact to and/or... General sense, energy issues you install and use your new pellet stove so. Before use, and getting hot at the tip within three minutes pellet vent when on the screen exclusions... Stove ignite cycle, do not need to start the stove to cool Down level will read at one. The desired operation mode - Weekly, Temp, and then press Enter to confirm the airflow holes new... Required by the regulatory authority having jurisdiction again to confirm most powerful and cleanest burning pellet stoves sold North! Top to bottom, fire prevention bureau, etc. stoves sold after may 15,.... Chambers top to bottom the rate of fuel that is specially designed to contain soot ) insert into a Fireplace. See the combination key function list below: Scroll Up to 3/4.Outside air damper... - Weekly, Temp, and may persist for several days proportional to the rate fuel. Fans, or even death clothing, furniture, draperies, and may persist several...

Vacuum Press Membrane, Articles C